Academy

Join our next webinars:


BlueVIS Masterclass 3.4 Advanced Soft sensors

Batch end detection. Learn how to utilize complex soft sensors to start the fed-batch feeding profile at the perfect time.
Oct 22 - Oct 22, 2024
11:30 am (CET – German time)

Join for free

BlueVIS Masterclass 3.5 Advanced Soft sensors - PID controlled RQ

Master the respiratory quotient and unlock the potential of PID controls to keep this critical process parameter stable in your process
Oct 24 - Oct 24, 2024
11:30 am (CET – German time)

Join for free
automated BMP biomethane potential determination

Yieldmaster automated BMP determination

Simultaneous measurement of CH4 concentration and volume

Technical Short Facts

  • Compliant to VDI 4630
  • No minimal gas flow needed
  • High sample throughput
  • Real-time values during methane production
  • Monitoring metabolism phenomena
  • Numerous samples in parallel means better comparability of results
  • Automatic data acquisition
  • High grade of automation

Yieldmaster components - choose what you need

  • BlueVCount gas volume measurement units
  • Fermenter bottles (250 ml to 5000 ml)
  • Software BlueVIS for data acquisition and calculations according to VDI 4630
  • BCP-CH4 sensors (optional)
  • Absorber bottles (NaOH) (optional)
  • Electronic multiplexer "BACCom" connection for up to 16 gas sensors (optional)
  • Water bath (optional)
  • Magnetic stirrer (optional)
  • Computer, display (optional)

The BMP (biomethane potential) test system „Yieldmaster“ is a sophisticated and modular analysis system. In its basic setup it consists of a gas bottle connected via tubing to BlueVCount, precision gas volume measurement device. It measures up to 80ml/min with a resolution of 1ml and consists of a volume measurement cell as well as temperature and pressure sensor. The volume measured of every single device is given as norm volume (273.15K 1.013 bar). Additionally, humidity can be compensated when necessary. For more advanced research tasks at universities or other research institutes the basic setup can be extended to also measure the gas concentration. Here we offer the well-known BCP gas analyzers for determination of CH4, CO2, H2, or O2. Direct installation at the fermentation vessel enables highly precise results and headspace corrections according to VDI 4630. Furthermore, kintec investigations of different substrate are feasible. Additional equipment like water bath, stirring, different glass reactors (250-5000ml), pH electrodes and pumps may be connected and controlled applying our cost effective open bioprocess software BlueVIS.

Measuring gas formation potential

To ensure effective biogas production determining the biological methane potential (BMP) of the input material is necessary. Yieldmaster simplifies BMPdetermination as well as comparison studies of different substrates and helps optimizing biogas yields. Using Yieldmaster you don't have to consider minimal gas productions. After starting the experiment, data for gas volume being produced and/or CH4 concentrations are logged automatically with BlueVis software. During fermentation in lab scale Yieldmaster can measure directly in the fermentation vessel. Like this, there will be no loss of data, headspace, as well as errors caused by gas leakage, will be minimized. Treatment or filtering the gas is not necessary. Combining methane sensors and BlueVCount results in continuous parallel biogas measurement. Gas volume produced as well as methane (biogas) concentration values measured are available online at any time.

Product-Video

Variations

BlueVIS

Biogas edition for up to 16 fermenters, incl. calculations according to VDI 4630

BlueVCount

volumetric meter up to 80 ml/min at a resolution of 1ml, integrated temperature and pressure sensor for automated normalisation of the measured volume.

Incl. accessories

  • cold trap/H2S absorber bottler incl. tubing
  • bottle (500 – 2.000 ml)
  • cable set / power supply

BCP Serie BCP-CH 4

Gas sensors, dual wavelength infrared sensor, 15-55°C, GL45 for bottle connection BCP-CH4 for up to 100 Vol.% CH4

BlueVIS

Biogas edition for up to 16 fermenters, incl. calculations according to VDI 4630

BlueVCount

volumetric meter up to 80 ml/min at a resolution of 1ml, integrated temperature and pressure sensor for automated normalisation of the measured volume.

Incl. accessories

  • cold trap/H2S absorber bottler incl. tubing
  • bottle (500 – 2.000 ml)
  • cable set / power supply

BCP Series BCP-CH 4

Gas sensors, dual wavelength infrared sensor, 15-55°C, GL45 for bottle connection BCP-CH4 for up to 100 Vol.% CH4

BlueVIS

Biogas edition for up to 16 fermenters, incl. calculations according to VDI 4630

BlueVCount

volumetric meter up to 80 ml/min at a resolution of 1ml, integrated temperature and pressure sensor for automated normalisation of the measured volume.

Incl. accessories

  • cold trap/H2S absorber bottler incl. tubing
  • bottle (500 – 2.000 ml)
  • cable set / power supply

Waterbath

Stirrer

Rack

Comparison Yieldmaster vs. Eudiometer

 YieldmasterEudiometer
Real time gas analysis in the process: no sampling
Detection of other important gases besides CH4 possibleadditional equipment needed
Optional pH probes connectableadditional equipment needed
Flexible scale
No gas treatment/filtering needed
Software for automated logging and managing of the process
Automated data acquisition of all values
Hazardous substances needed

Complete system with PC

We can also offer a preconfigured Yieldmaster complete system with BlueVis, a very powerful PC, a monitor, mouse and water-resistant keyboard. The Yieldmaster complete system is individually pre-installed for you at BlueSens so that you can quickly start the measurement. Just contact us for the complete system with PC.


Flow adapter for inexpensive fermentation vessels

Inexpensive measurement of biogas in the laboratory

Especially for use in the Yieldmaster systems there is a special flow adapter for use along with inexpensive preserving jars to choose from now. The flow adapter can be easily connected to round jars with a volume of up to five liters and provides two connectors for BCP-sensors. In most cases the set-up consists of a CH4 and a CO2 sensor, but for other types of experiments there are other possible installations (for example, CH4 / O2 or CH4 / H2). In addition, the flow adapter has a standardized PG13.5 port through which, for example, an additional probe can be installed. The experiments for the production of Biomethane often last for several days. Often it is recommended to run a larger number of experiments at the same time run enough variations and comparison tests in a manageable timeframe. The use of inexpensive jars in this case represents an attractive alternative to traditional fermentation vessels and small fermenters.

Yieldmaster consist of

Downloads